3. With the unit still in the “Home” position, loosely attach the stop collar.
Align the sliding nut and bolt such that it is centered in the slot. Next, align that
bolt with the Button Head Cap Screw which is directly under the connector. Adjust
the height of the stop collar so the head of the “sliding” bolt is just above the
Button Head Cap Screw. Tighten the stop collar onto the Pan & Tilt unit.
4. Using the controls in ProScan, verify the Pan and Tilt can rotate from -180
degrees to +180 degrees in the Pan axis. The head of the sliding bolt should
come in contact with the head of the Socket Head Cap Screw and slide in
the slot.